11-Oct-2019 |
|
(ID 780) MainView AutoOPERATOR: An integrity issue affects MainView AutoOPERATOR and MainView Total Object Manager |
PDF |
10-Oct-2019 |
|
(ID 781) MainView Infrastructure: An integrity issue affects all MainView products when you invoke them using the MainView
CLIST |
PDF |
07-Oct-2019 |
|
UPDATED (ID 761) MainView Logger: NGL might cause serious problems in the DBC address space, including loops and abends |
PDF |
04-Oct-2019 |
|
(ID 773) MainView products using a LOAD library in their address spaces might experience errors |
PDF |
11-Jul-2019 |
|
(ID 718) MainView Logger: NGL might cause serious problems in the DBC address space, including loops and abends |
PDF |
18-Apr-2019 |
|
UPDATED (ID 661) All products that run in the DBC component: An abend in BBM0ZLCS or OSZXCNSL might cause a storage overlay problem in the private area of the DBC address space |
PDF |
11-Apr-2019 |
|
(ID 653) All MainView products: An abend in BBM0ZLCS or OSZXCNSL might cause a storage overlay problem in the private area of the DBC address space |
PDF |
11-Jan-2019 |
|
MainView Infrastructure: UPDATED MainView Alternate Access does not operate if IBM PTF UA98016 or UA98017 is applied |
PDF |
20-Dec-2018 |
|
MainView Infrastructure: MainView Alternate Access does not operate if IBM PTF UA98016 or UA98017 is applied |
PDF |
07-Dec-2018 |
|
MainView for z/OS, CMF MONITOR, MainView SYSPROG Services, MainView for UNIX System Services, and MainView AutoOPERATOR: A CSA overlay might occur if you reinitialize the BBX subsystem by using the BBXSINIT program instead of an IPL |
PDF |
17-Oct-2017 |
|
MainView AutoOPERATOR Flash: After you apply PTF BQI2287, an abend 878 might occur in the CICS region |
PDF |
23-Feb-2017 |
|
MainView for z/OS, CMF MONITOR, MainView SYSPROG Services, Discovery for z/OS, MainView AutoOPERATOR: After applying PTF BPB1407, you might experience an abend S0C4 during I/O reconfiguration or re-initialization of the BBXS Subsystem |
PDF |
16-Jan-2017 |
|
MainView for CICS and MainView AutoOPERATOR: After applying PTF BPZ0775 or BPZ0776, you might receive message FT126S and a IBM CICS SOS condition might occur |
PDF |
14-Jun-2016 |
|
BMC Runtime Component System: Applying PTF BP00336 or BP00337 when using CA ACF2 Release 15, or using CA ACF2 Version 16 without applying the PTFs, will cause a security failure to occur in MainView products |
PDF |
09-May-2016 |
|
MainView AutoOPERATOR for CICS and MainView for CICS: Commands from the product address space (PAS) to an IBM CICS region might be suspended |
PDF |
29-Apr-2016 |
|
MainView AutoOPERATOR for CICS and MainView for CICS: Applying PTF BPZ0753 or installing certain versions of the product might cause S0C4 abends in BBI-SS PAS, followed by problems reconnecting to CICS targets |
PDF |
14-Apr-2016 |
|
MainView Infrastructure: An expired certificate causes Java Security to block access to MainView Explorer |
PDF |
29-Jan-2016 |
|
MainView Infrastructure: Applying PTF BQY0926 causes MVE to use incorrect credentials to access views and data |
PDF |
05-Nov-2015 |
|
MainView AutoOPERATOR and MainView for CICS: After you apply PTF BPZ0743, a CICS region might not process action commands that you send manually or via MainView AutoOPERATOR EXECs |
PDF |
23-Oct-2015 |
|
MainView Total Object Manager: MainView Total Object Manager might not start, stop, or update objects' statuses correctly because of Daylight Saving Time changes |
PDF |
29-May-2015 |
|
MainView Products: A performance issue occurs when running MainView products on an IBM z13 processor |
PDF |
16-Apr-2015 |
|
MainView AutoOPERATOR for z/OS: A potential security exposure occurs in the product when it is running with the MainView SYSPROG Services 3.8.00 component and PTF BQM1090 has been applied. |
PDF |
23-Feb-2015 |
|
MainView AutoOPERATOR: The PASPARM view does not restrict who can access or edit BBPARM members from the
view |
PDF |
20-Feb-2015 |
|
MainView AutoOPERATOR: Any automation from earlier versions of MainView AutoOPERATOR that includes the AOEXEC VLST command fails in version 7.4.00 |
PDF |
12-Feb-2015 |
|
MainView AutoOPERATOR: A storage overlay of high private storage might occur when you access arrays with
MainView AutoOPERATOR EXECs |
PDF |
12-Dec-2014 |
|
MainView AutoOPERATOR: Ensure customers apply maintenance PTF after installing version 7.4.00 |
PDF |
Technical Bulletin
|
03-Jan-2020 |
|
(ID 834) Maintenance: RSL2001 and RSL2001C are available |
PDF |
17-Dec-2019 |
|
(ID 786) Maintenance: BMC now supports IBM SMP/E RECEIVE ORDER for BMC mainframe products |
PDF |
06-Nov-2019 |
|
(ID 801) An outage is scheduled for filedownload.bmc.com services, BMC ISR, and EPD |
PDF |
17-Oct-2019 |
|
(ID 750) MainView Alternate Access now includes a TIMEOUT parameter |
PDF |
10-Oct-2019 |
|
(ID 782) MainView Infrastructure: A new REST API allows users to access MainView data from outside of MainView. This enables using MainView dat in other tools for reporting and analysis. |
PDF |
03-Oct-2019 |
|
(ID 772) RSL1910 is available |
PDF |
19-Sep-2019 |
|
(ID 724) MainView Infrastructure: MainView Alarm Management deployment enhancements are now available |
PDF |
05-Sep-2019 |
|
(ID 737) MainView Explorer now includes a TIMEOUT parameter |
PDF |
04-Sep-2019 |
|
(ID 736) Installation and maintenance: Scheduled outage for filedownload.bmc.com services and BMC ISR, server changes, and new EV SSL certificate |
PDF |
30-Aug-2019 |
|
(ID 752) Customer Support: BMC is announcing a new method for sending information to Customer Support |
PDF |
08-Aug-2019 |
|
(ID 692) A utility to extract records for offloaded BBI-SS PAS journal data sets to CSV formatted data sets is available |
PDF |
07-Aug-2019 |
|
(ID 735) All supported BMC mainframe products: You can now use your favorite search engine to find information in BMC product documentation |
PDF |
03-Jul-2019 |
|
(ID 710) Maintenance: RSL1907 and RSL1907C are available |
PDF |
05-Jun-2019 |
|
(ID 681) New passwords for the ESD FTP and BMC ISR FTP sites take effect at 00:00 Coordinated Universal Time (UTC) on July 3, 2019 |
PDF |
07-May-2019 |
|
(ID 666) MainView Infrastructure: An S0C4 abend may occur
in MainView identified as ????????(????????+********) |
PDF |
01-May-2019 |
|
UPDATED (ID 664) MainView Infrastructure: Applying PTF BQY1876, BQY1877, or BQY1878 can delay PAS initialization |
PDF |
03-Apr-2019 |
|
(ID 642) Maintenance — RSL1904 is available |
PDF |
27-Mar-2019 |
|
Applying PTF BQY1876, BQY1877, or BQY1878 can delay PAS initialization |
PDF |
17-Jan-2019 |
|
MainView Infrastructure now supports TCP/IP encryption |
PDF |
03-Jan-2019 |
|
RSL1901 and RSL1901C are available |
PDF |
24-Dec-2018 |
|
BMC ISR extract job $E05XTRT and retrieve job $J05RETV are missing the COPYSTEP and SFTP steps |
PDF |
04-Oct-2018 |
|
Maintenance: RSL1810 is available |
PDF |
13-Sep-2018 |
|
MainView Infrastructure: MainView Explorer can now be launched from a stand-alone package |
PDF |
03-Jul-2018 |
|
Maintenance: RSL1807 and RSL1807C are available |
PDF |
21-Jun-2018 |
|
MainView Infrastructure: After applying PTF BQY1469 or BQY1470, MainView Logger logs all WTOs, regardless of the WTOLOG or LOGWTO parameter setting |
PDF |
30-May-2018 |
|
Announcing support for FIXCAT categories for Enhanced HOLDDATA |
PDF |
05-Apr-2018 |
|
Maintenance: RSL1804 is available |
PDF |
16-Mar-2018 |
|
MainView AutoOPERATOR: MainView AutoOPERATOR TIME Rules and EXECs will encounter errors when the system clock is changed for daylight saving time |
PDF |
02-Feb-2018 |
|
Customer Support: Changes for sending files to Customer Support through ftp.bmc.com |
PDF |
03-Jan-2018 |
|
Maintenance: RSL1801 and RSL1801C are available |
PDF |
14-Dec-2017 |
|
MainView Explorer hangs when MVI host server restarted with SSL=N |
PDF |
14-Dec-2017 |
|
MainView Infrastructure December 2017 enhancements for version 6.2 are available |
PDF |
16-Nov-2017 |
|
BMC is announcing licensing permission for running BMC products and solutions for IBM z/OS in the IBM zD&T and zPDT environments but will not extend BMC Customer Support services to the virtual environments |
PDF |
05-Oct-2017 |
QM002280140 |
MainView Infrastructure now reduces Data Dictionary overhead in metrics-related views |
PDF |
02-Oct-2017 |
|
Maintenance: RSL1710 is available |
PDF |
29-Sep-2017 |
|
MainView products now support running on Version 2.3 of the IBM z/OS system |
PDF |
28-Sep-2017 |
|
MainView Infrastructure: MainView Explorer can now graph to a secondary Y-axis scale and integrate with IBM z/OSMF |
PDF |
06-Jul-2017 |
|
Maintenance: RSL1707 and RSL1707C are available |
PDF |
14-Jun-2017 |
|
New passwords for the ESD FTP and BMC ISR FTP sites take effect at 00:00 Coordinated Universal Time (UTC) on July 6, 2017 |
PDF |
10-May-2017 |
|
UIM: Announcing support for versions 1.1 and 1.2 of TLS |
PDF |
27-Apr-2017 |
|
Quicker and easier access to BMC mainframe product documentation is now available |
PDF |
04-Apr-2017 |
|
Maintenance: RSL1704 is available |
PDF |
10-Feb-2017 |
|
RTCS: The OSZHTML hypertext document library in the RTCS subsystem start-up procedure is no longer required |
PDF |
01-Feb-2017 |
|
MainView Infrastructure: MVALARM 2.1 will be no longer available with MainView Infrastructure 6.2 |
PDF |
04-Jan-2017 |
|
Maintenance: RSL1701 and RSL1701C are available |
PDF |
09-Dec-2016 |
|
UIM: BMC is providing instructions for creating SSL/TLS certificates for use with UIM |
PDF |
03-Oct-2016 |
|
Maintenance: RSL1610 is available |
PDF |
18-Aug-2016 |
|
BMC ISR: BMC has scheduled an outage for BMC Internet Service Retrieval (BMC ISR) |
PDF |
06-Jul-2016 |
|
Installation System: RSL1607 and RSL1607C are available |
PDF |
16-Jun-2016 |
|
Installation System: New passwords for the ESD and BMC ISR FTP sites take effect at 00:00 Coordinated Universal Time (UTC) on July 6, 2016 |
PDF |
01-May-2016 |
|
MainView Infrastructure: When browsers phase out support for NPAPI plugins, MainView Explorer will not run as an applet in those browsers |
PDF |
18-Mar-2016 |
|
Installation System: Announcing release, maintenance, and service levels |
PDF |
18-Mar-2016 |
|
RSL: Introducing Recommended Service Level (RSL) maintenance |
PDF |
04-Dec-2015 |
|
PUT1502B is available |
PDF |
12-Oct-2015 |
|
MainView AutoOPERATOR: BMC is announcing the new MainView AutoOPERATOR Enterprise Incident Management
(EIM) solution that generates Remedy trouble tickets |
PDF |
01-Oct-2015 |
|
MainView Infrastructure: Enhancements to MainView Infrastructure to support UIM/USC usage and HTTPS |
PDF |
10-Aug-2015 |
|
BMC is providing additional considerations for users who migrate to version 2.3.00 of MainView TOM (a component of the MainView AutoOPERATOR product) from an earlier version. |
PDF |
22-Jul-2015 |
|
Installation System: $177ACCF job fails |
PDF |
29-Jun-2015 |
|
BMC Runtime Component System: An enhancement adds new commands to simplify operational shutdown |
PDF |
01-Jun-2015 |
|
Installation System: Enable configuration and running of products from SMP/E target libraries |
PDF |
18-May-2015 |
|
MainView Infrastructure: Correcting PTF available: A CPU loop can occur in the PAS if the BBIPARM DD statement
defines only one data set |
PDF |
08-May-2015 |
|
MainView AutoOPERATOR for CICS: New security definitions are required after applying PTF BQO1628 or BQO1629 |
PDF |
06-May-2015 |
|
PUT1501B is available |
PDF |
05-Apr-2015 |
|
Installation System: New passwords for the ESD and BMC ISR FTP sites take effect at 00:00 Coordinated
Universal Time (UTC) on May 5, 2015 |
PDF |
25-Mar-2015 |
QM001875896 |
Updated - MainView Infrastructure: A CPU loop can occur in the PAS if the BBIPARM DD statement defines only one data set. |
PDF |
09-Mar-2015 |
|
BMC Documentation Center: The primary Documentation Center is now available without a support login. |
PDF |
13-Feb-2015 |
|
MainView AutoOPERATOR: MainView Total Object Manager (TOM) no longer unconditionally starts an object when a
START command is issued |
PDF |
13-Feb-2015 |
|
MainView AutoOPERATOR: You must redefine some MainView Total Object Manager (TOM) UPM objects that were defined in version 2.2.00 (or earlier) to work in version 2.3.00 |
PDF |
30-Jan-2015 |
|
MainView Infrastructure: The MainView Explorer client session will now reconnect to the MainView host server automatically after an interruption. |
PDF |
09-Jan-2015 |
|
Installation System: New requirement for MainView product installation |
PDF |
Release Notes
|
13-Jun-2019 |
|
Installation System: Announces changes and new features in version 3.11.00 |
PDF |
13-Dec-2018 |
|
Installation System: Announces changes and new features in version 3.9.00 |
PDF |
21-Jun-2018 |
|
MainView Infrastructure: Describes what is new and changed in MainView Infrastructure version 6.3.00 |
PDF |
03-May-2018 |
|
Installation System: Announces changes and new features in version 3.6.00 |
PDF |
14-Dec-2017 |
|
Installation System: Announces changes and new features in version 3.5.00 |
PDF |
22-Jun-2017 |
|
Installation System: Announces changes and new features in version 3.3.00 |
PDF |
23-Mar-2017 |
|
MainView Infrastructure: Describes what is new and changed in MainView Infrastructure version 6.2.00 |
PDF |
22-Mar-2017 |
|
Installation System: Announces changes and new features in version 3.2.00 |
PDF |
08-Dec-2016 |
|
Installation System: Announces changes and new features in version 3.1.00 |
PDF |
22-Sep-2016 |
|
MainView Infrastructure: Describes what is new and changed in MainView Infrastructure version 6.1.01 |
PDF |
04-Dec-2015 |
|
Installation System and RTCS: Announces changes and new features in versions 3.0.00 and 2.1.00, respectively |
PDF |
06-May-2015 |
|
Installation System: Announces changes and new features in version 2.4.10 |
PDF |
12-Feb-2015 |
|
Installation System: Announces changes and new features in version 2.4.05 |
PDF |
29-Dec-2014 |
|
Installation System: Updated - Announces changes and new features in version 2.4.00
|
PDF |
05-Dec-2014 |
|
BMC Impact Integration for z/OS component of MainView AutoOPERATOR: Announces changes and new features in version 1.6.00
|
PDF |
05-Dec-2014 |
|
MainView AutoOPERATOR: Announces changes and new features in MainView AutoOPERATOR 7.4 and MainView Total Object Manager version 2.3. |
PDF |
Online Technical Documentation
|
29-Feb-2024 |
|
Online documentation for the current version of the Installation System |
HTM |
03-May-2017 |
|
Online documentation for MainView AutoOPERATOR, previous versions |
HTM |
06-Feb-2018 |
|
Online documentation for MainView Automation, previous versions |
HTM |
14-Dec-2017 |
|
Online documentation for MainView Message Management |
HTM |
14-Dec-2017 |
|
Online documentation for MainView for IMS Management |
HTM |
14-Dec-2017 |
|
Online documentation for MainView for Networks |
HTM |